MIMPLEX Gas Alarm Panels

Central / Repeater Panels

The Mimplex multiplexed alarm panel continuously monitors medical gas installations. Up to 6 gases can be displayed per panel with 4 Conditions available per gas. The system is easy to operate and install with only 1 pair cable being necessary interconnecting wiring.

The Mimplex Alarm System meets and exceeds the current C11 and HTM2022 specifications.

Central/Repeater Panel .jpg '14KB'
 
The Unit also offers:
  • All electronics contained in an attractive, white stove enamelled, robust metal enclosure
  • Access to the panel is via hinged front door with tamperproof screw
  • Panels available for either flush or surface mounting applications
  • Open and Short Circuit indication
  • Mute indication i.e. light illuminates when mute button pressed
  • Volume control, permanent mute button and engineers reset button all easily accessed
  • Each panel has an easy self-check/test procedure

Plant Encoders

Plant Encoders (transmitters) are usually located in the plant room and commonly in the plant to be monitored hence reducing wiring to a minimum.

  • Self Powered from Multiplex
  • Capable of transmitting up to 4 alarm condition
Plant Encoder .jpg '6KB'
 
Local/Area Alarm Panel .jpg '12KB'

Local/Area Alarm Panel

The Mimplex Local/Area Alarm Panel can monitor up to 6 gas services, each service consisting of 2 conditions.

  • All panel functions are similar to the Central panel including all box dimensions.
  • Individual pressure switches are hard-wired into the panel via End of Line (E.O.L.) Modules which enable open, short circuit or zenner barrier detection.
                                                                                                                High/Low Pressure Switch
                                                                                                                Assembly with MIN Leak
End Of Line Module .gif '8KB' Pressure Switches .gif '9KB'
              End Of Line Module                                     Low Vacuum Pressure Switch
                                                                                     Assembly with MIN Leak
 

Typical Hospital Layout

Diagram of a Typical Hospital Layout .gif '13KB'

  • Flexible layout design - new panels can be added anywhere in the system.
  • Up to 84 separate alarm conditions (18 encoders) per system.

Also Available

  • BMS Relay Interface Unit - Board consisting of a bank of 24 normally open/closed relays used for interfacing the system to any external system.
  • Remote Audible - activated by either BMS contacts or audible contacts on Mimplex Panels, mounted in perhaps adjacent corridor to provide enhanced warning.

Panel Dimensions

Panel Dimensions .gif '6KB'